<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-05 02-01-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
90.90 MHz 4/5, 62 dBuV CHANTE F
Pilot RDS Phase Difference
6.6 kHz 3.9 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 73 kHz 10058 0,2187
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,1 dBr 7,62 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"CHANTE F" FE43 0 (No PTY) 1 0 1 2 2:01, 5.05.2025
RT
"FRANCIS CABREL - QUESTION D'EQUILIBRE "
AF EON
90.9, 96.7 MHz -
FM Scope Station: 90.90 MHz, signal: 4/5 (62 dBuV) Max at: 73 kHz MIN: 17 kHz % above 76 kHz: 0,2187 Acquired: 2025/05/05 2:00:01 Total samples: 10058 Equivalent time: 0:08:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,3 dBr MIN: 7,1 dBr AVE: 7,62 dBr % above 10,2 dBr: 0,0 Last value: 8,1 dBr (2025/05/05 2:00:01) Station: 90.90 MHz, signal: 4/5 (62 dBuV) 01:53 01:54 01:55 01:56 01:57 01:58 01:59 02:00 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality